Gas Fireplace Repair in Pomona

What Are You Hearing Up There?

Inside the Visit

A gas fireplace that ticks without catching, or catches and then dies, often has a plain cause: a dirty sensor, a worn pilot part, a weak battery in the receiver, or insects nesting where the flame should be. We test each part in turn, replace only what failed with parts made for that model, check every joint we open for leaks and run the fireplace before leaving. The price follows the part.

Pilot, sensor and igniter tested one at a time
Insect nests removed from the pilot tube
Remote receivers and wall switches checked
Leak test on every joint we open
Full burn run before we pack up

Faults That Start With an Animal

More gas fireplace calls in Pomona lead back to animals than owners would guess. Mice move into the space under the firebox in fall because it is warm and dark, and they chew wiring: the leads from the pilot generator, the wires to the wall switch, the harness to the ignition module. Birds and wasps pack the vent cap outside, the unit senses the poor draft and shuts itself down, or the flame lifts and goes ragged. Spiders spin webs inside the pilot tube and the pilot will not hold. In each case the fireplace looks broken and the part looks fine. So we begin with the vent and the space under the unit before replacing anything. Droppings, nest material or a chewed wire there usually tell the story, and fixing the cause stops the same fault coming back next year. A new part on a unit with mice still living under it just gives them something fresh to chew.

Not every fault has fur. Every standing pilot unit has a safety loop: the pilot heats a sensor, the sensor holds the gas valve open, and when the heat goes away the valve closes. When that loop weakens with age or soot, you get a pilot that won't hold on its own, or a main flame that drops out after a few minutes of running. Units with electronic ignition have a module, a battery backup and a flame sensor, and any of those can fail. We also check the gas pressure at the valve and the valve itself, since a valve that is wearing out can mimic a bad sensor. When a unit is old enough that its maker no longer supplies parts, the talk turns to replacing it, and the insert page covers that route. Either way, you hear what failed and why before a part is ordered.

Gas Smell, Soot and the Price

A gas smell near the fireplace is not something to book for next week. If you smell it, leave the unit and the light switches alone, walk everyone out of the house, and ring your gas supplier once you are outdoors. When the supplier has cleared the house, book us to track down where it came from; leaks at a fireplace are usually at a fitting, the valve or a flexible connector. Soot is the other warning to take seriously. If black marks creep up the face above the glass, or a carbon monoxide alarm goes off with the fireplace running, switch it off and leave it off until it has been looked at. Soot means the gas is not burning cleanly, and in a vented unit that often means the vent is part blocked, which brings us straight back to the nest or the wasp tubes in the cap outside.

The repair price comes after the fault is found. A new sensor, a fresh switch wire or a cleared vent cap is a small job; a gas valve or a control module costs more because of the part itself. You learn which it is and what it costs before we order anything, and if the part has to come from the maker we tell you that too. If the vent cap outside has no guard, or one that birds have already broken through, we tell you whether one is made for that unit and price it alongside. Before we leave, the unit runs through a full cycle with you there and the fittings we touched are tested. When you write in through the contact page, mention what happens at the switch or knob when you try to light it, and anything you have found under the unit, like droppings, shredded paper or chewed wire.

Four Habits on Every Sloane Chimney Care Job

Roof Checked Too

Cap, screen and crown looked at whatever the call

Mess Bagged Out

Nests, leaves and soot leave the house with us

Price on Paper

You see each line before anyone starts

Photos to Keep

Pictures of the flue and the top when we finish

Other Work We Take On

Chimney Sweep

Nests, leaves and soot pulled down the flue with rods and brushes, and the smoke shelf scooped clear of whatever landed on it.

Read more →

Chimney Inspection

A walk over the firebox, damper, flue opening and roof top to find out what is living up there or getting in.

Read more →

Chimney Repair

Cracked, chewed or loose parts of the chimney put back in order, from wobbly top bricks to a crown with gaps under it.

Read more →

Fireplace Inspection

The room side looked over: firebox, damper, hearth and doors, with an eye out for droppings, stains and smells that point upward.

Read more →

Fireplace Repair

Firebrick, joints, damper and doors set right after wear, heat or a nesting season left the fireplace unfit to use.

Read more →

Chimney Level 2 Inspection

A camera sent up the whole flue for nests and blockages neither end can show, with a recording and a written report.

Read more →

Chimney Cap Installation

A mesh-sided stainless cap measured to the flue top, so birds, raccoons, squirrels and blown leaves stay out on the roof.

Read more →

Chimney Flashing Repair

Metal at the roof line resealed where water, roof rats or squirrels found a gap between the brick and the shingles.

Read more →

Chimney Masonry Repair

Open joints and crumbling brick rebuilt so rain, bees and mice stop finding a way into the stack.

Read more →

Chimney Rebuilds

A stack too loose to patch taken down and laid up again, with a cap and screen on top at the finish.

Read more →

Fireplace Cleaning

Ash, soot, fallen nest and the odd feather cleared from the firebox and smoke shelf, with the doors and face wiped down.

Read more →

Gas Fireplace Cleaning

Burner, ports, logs and glass cleaned on a gas unit, and the outside vent checked for nests, webs and lint.

Read more →

Fireplace Remodel

A dated fireplace face replaced with new tile, stone or plaster, once the firebox behind it passes a check.

Read more →

Fireplace Inserts

An insert fills the old fireplace, runs its own liner up the stack and leaves no open flue for drafts or animals.

Read more →

Pellet Stove Repair

Jammed feeds, smoky starts and mid-burn shutdowns sorted on pellet stoves, plus the vent cleared of ash and outside nests.

Read more →

Wood Stove Repair

Wood stoves put right: door seals, glass, baffles and firebrick, plus the stovepipe and its top checked for nests.

Read more →

Gas Logs

Vented gas logs for owners who want the flame without hauling wood, set up once the flue is clear of nests.

Read more →

Chimney Seismic Retrofit

Brick stacks braced, strapped or rebuilt lighter so the top of the chimney is less likely to fall in a strong quake.

Read more →

Chimney Crown Repair

Cracked chimney tops sealed or poured again, ending the water and the wasp nests that move into the gaps.

Read more →

Dryer Vent Cleaning

Lint packed in the duct and nests in the outside hood cleared, so the dryer finishes a load and the laundry room stays cool.

Read more →

Chimney Liner Installation

Stainless liners set inside a cracked or bare flue and topped with a cap, so the new tube never becomes a nesting tube.

Read more →

Chimney Leak Repair

Water in the attic or a wet ceiling by the chimney followed to its source, often a gap an animal widened, then sealed.

Read more →

Chimney Waterproofing

Water repellent sprayed on the outside brick to slow soaking, done last after cracks, joints and metal have been repaired.

Read more →

Chimney Damper Repair

Dampers that stick, rattle or no longer shut fixed or replaced, so cold air, smells and small animals stay up in the flue.

Read more →

Chimney Chase Cover

Rusted lids on framed chimneys replaced with stainless ones cut to measure, with a screened cap where the pipe exits.

Read more →